| Power |
212 |
kW |
| Input DC Voltage (including HV supply voltage) |
|
|
| Typical Input DC undervoltage shutdown |
100 |
V |
| Minimum Input DC voltage for operation |
120 |
V |
| Minimum Input DC voltage for full current capability |
200 |
V |
| Maximum Input DCvoltage for operation |
480 |
V |
| Typical Input DC overvoltage shutdown |
500 |
V |
| Maximum Input DC surviving voltage |
520 |
V |
| Three Phase AC Output |
|
|
| Continuous RMS current |
450 |
A |
| Repetitive max. RMS current 30sec 100%, 90sec 50% |
600 |
A |
| Peak RMS current derating vs. Tcoolant>72°C. |
-20 |
A/°C |
| Cont. Power (VDC=75%VDCmax, IAC=IACcont, cos phi=0,9) (note 1) |
160 |
kW |
| Max. Power (VDC=75%VDCmax, IAC=IACmax, cos phi=0,9) (note 1) |
212 |
kW |
| PWM Frequency (symmetrical modulation) |
24 |
kHz |
| Efficiency (VDC=75%VDCmax, PAC=PACcont, cos phi=0,9) (note 1) |
0.97 |
|
| Mechanical and Environment |
|
|
| Height |
88 |
mm |
| Width |
240 |
mm |
| Length (without connections and cable clamps) |
580 |
mm |
| Weight (including cooling water) |
15 |
kg |
| Coolant pressure drop @ 6l/min, Tcoolant = 25°C (note 2) |
100 |
hPa |
| Power dissipation to coolant (IAC = IACcont) |
4.8 |
kW |
| Operational ambient temperature range |
-40...+85 |
°C |
| protection grade |
IP65 |
|
| Connections |
|
|
| DC Input: 2 cable shoes M8; max cable cross section |
120 |
mm2 |
| AC output: 3 cable shoes M8; max cable cross section |
120 |
mm2 |
| 23 pole AMP control connector, wire cross section |
0.5 |
mm2 |
| Universal 14 pole Motor Sensor Interface connector |
|
|
| Recommended coolant hose inside diameter |
14 |
mm |
| Note 1: 100% AC Sine Modulation, Phase-to-Phase AC Voltage amplitude = VDC |
|
|
| Note 2: coolant = water / glycol, 50/50 |
|
|