Products            BRUSA ISO9001 Certificate
Deutsch | English
 DMC518DMC528DMC548 
Power53106212kW
Input DC Voltage (including HV supply voltage)
Typical Input DC undervoltage shutdown200200200V
Minimum Input DC voltage for operation240240240V
Minimum Input DC voltage for full current capability400400400V
Maximum Input DCvoltage for operation960960960V
Typical Input DC overvoltage shutdown100010001000V
Maximum Input DC surviving voltage112011201120V
Three Phase AC Output
Continuous RMS current56112225A
Repetitive max. RMS current 30sec 100%, 90sec 50%75150300A
Peak RMS current derating vs. Tcoolant>72°C.-2.5-5-10A/°C
Cont. Power (VDC=75%VDCmax, IAC=IACcont, cos phi=0,9) (note 1)4080160kW
Max. Power (VDC=75%VDCmax, IAC=IACmax, cos phi=0,9) (note 1)53106212kW
PWM Frequency (symmetrical modulation)161616kHz
Efficiency (VDC=75%VDCmax, PAC=PACcont, cos phi=0,9) (note 1)0.970.970.97
Mechanical and Environment
Height888888mm
Width240240240mm
Length (without connections and cable clamps)250360580mm
Weight (including cooling water)6.59.515kg
Coolant pressure drop @ 6l/min, Tcoolant = 25°C (note 2)5065100hPa
Power dissipation to coolant (IAC = IACcont)1.22.44.8kW
Operational ambient temperature range-40...+85-40...+85-40...+85°C
protection gradeIP65IP65IP65
Connections
DC Input: 2 cable shoes M8; max cable cross section505070mm2
AC output: 3 cable shoes M8; max cable cross section505070mm2
23 pole AMP control connector, wire cross section0.50.50.5mm2
Universal 14 pole Motor Sensor Interface connector
Recommended coolant hose inside diameter141414mm
Note 1: 100% AC Sine Modulation, Phase-to-Phase AC Voltage amplitude = VDC
Note 2: coolant = water / glycol, 50/50
Preis0.000.000.00CHF
 
BRUSA Elektronik AG   Neudorf 14   Postfach 55   CH-9466 Sennwald   Switzerland
Tel: +41 (0)81 758 19 00   Fax: +41 (0)81 758 19 99   E-mail:
info@brusa.biz