| | DMC514 | DMC524 | DMC544 | |
|---|
| Power | 53 | 106 | 212 | kW |
| Input DC Voltage (including HV supply voltage) | | | | |
| Typical Input DC undervoltage shutdown | 100 | 100 | 100 | V |
| Minimum Input DC voltage for operation | 120 | 120 | 120 | V |
| Minimum Input DC voltage for full current capability | 200 | 200 | 200 | V |
| Maximum Input DCvoltage for operation | 480 | 480 | 480 | V |
| Typical Input DC overvoltage shutdown | 500 | 500 | 500 | V |
| Maximum Input DC surviving voltage | 520 | 520 | 520 | V |
| Three Phase AC Output | | | | |
| Continuous RMS current | 112 | 225 | 450 | A |
| Repetitive max. RMS current 30sec 100%, 90sec 50% | 150 | 300 | 600 | A |
| Peak RMS current derating vs. Tcoolant>72°C. | -5 | -10 | -20 | A/°C |
| Cont. Power (VDC=75%VDCmax, IAC=IACcont, cos phi=0,9) (note 1) | 40 | 80 | 160 | kW |
| Max. Power (VDC=75%VDCmax, IAC=IACmax, cos phi=0,9) (note 1) | 53 | 106 | 212 | kW |
| PWM Frequency (symmetrical modulation) | 24 | 24 | 24 | kHz |
| Efficiency (VDC=75%VDCmax, PAC=PACcont, cos phi=0,9) (note 1) | 0.97 | 0.97 | 0.97 | |
| Mechanical and Environment | | | | |
| Height | 88 | 88 | 88 | mm |
| Width | 240 | 240 | 240 | mm |
| Length (without connections and cable clamps) | 250 | 360 | 580 | mm |
| Weight (including cooling water) | 6.5 | 9.5 | 15 | kg |
| Coolant pressure drop @ 6l/min, Tcoolant = 25°C (note 2) | 50 | 65 | 100 | hPa |
| Power dissipation to coolant (IAC = IACcont) | 1.2 | 2.4 | 4.8 | kW |
| Operational ambient temperature range | -40...+85 | -40...+85 | -40...+85 | °C |
| protection grade | IP65 | IP65 | IP65 | |
| Connections | | | | |
| DC Input: 2 cable shoes M8; max cable cross section | 50 | 70 | 120 | mm2 |
| AC output: 3 cable shoes M8; max cable cross section | 50 | 70 | 120 | mm2 |
| 23 pole AMP control connector, wire cross section | 0.5 | 0.5 | 0.5 | mm2 |
| Universal 14 pole Motor Sensor Interface connector | | | | |
| Recommended coolant hose inside diameter | 14 | 14 | 14 | mm |
| Note 1: 100% AC Sine Modulation, Phase-to-Phase AC Voltage amplitude = VDC | | | | |
| Note 2: coolant = water / glycol, 50/50 | | | | |
| Preis | 0.00 | 0.00 | 0.00 | CHF |