| High voltage side | | |
| HV-voltage range | 400 - 900 | V |
| Low voltage side | | |
| LV-voltage nominal | 28.0 | V |
| LV-voltage range | 18 - 32 | V |
| Performance | | |
LV-continuous current (@ Tcoolant = 65°C) | 100 | A |
| LV-maximum current | 125 | A |
Continuous power (@ ULV = Unom ) | 2.8 | kW |
Maximum power (@ ULV = Unom ) | 3.5 | kW |
| Efficiency typ. | >91 | % |
| Switching frequency buck/boost stage | 40-130 | kHz |
| Switching frequency transformer stage | 200 | kHz |
| Control | | |
| Control bandwidth (3dB - point) | ~ 1 | kHz |
| Control accuracy of LV-voltage (buck mode) | < 0.2 | V |
| Control accuracy of HV-voltage (boost mode) | < 1.0 | % |
| Mechanical and environmental conditions | | |
| Cooling system | Liquid (50% water, 50% ethylene glycol) | |
| Nominal flow rate | 4 | l/min |
Pressure drop (@ nominal flow rate) | < 0.1 | bar |
| Ambient temperature range (storage) | -40 - +105 | °C |
| Ambient temperature range (operation) | -40 - +85 | °C |
| Maximum coolant temperature | 65 | °C |
| Ingress protection class | IP65 | |
| Dimensions | 300 x 150 x 70 | mm |
| Weight | 4.7 | kg |