| Power | 106 | kW |
| Input DC Voltage (including HV supply voltage) | | |
| Typical Input DC undervoltage shutdown | 200 | V |
| Minimum Input DC voltage for operation | 240 | V |
| Minimum Input DC voltage for full current capability | 400 | V |
| Maximum Input DCvoltage for operation | 960 | V |
| Typical Input DC overvoltage shutdown | 1000 | V |
| Maximum Input DC surviving voltage | 1120 | V |
| Three Phase AC Output | | |
| Continuous RMS current | 112 | A |
| Repetitive max. RMS current 30sec 100%, 90sec 50% | 150 | A |
| Peak RMS current derating vs. Tcoolant>72°C. | -5 | A/°C |
| Cont. Power (VDC=75%VDCmax, IAC=IACcont, cos phi=0,9) (note 1) | 80 | kW |
| Max. Power (VDC=75%VDCmax, IAC=IACmax, cos phi=0,9) (note 1) | 106 | kW |
| PWM Frequency (symmetrical modulation) | 16 | kHz |
| Efficiency (VDC=75%VDCmax, PAC=PACcont, cos phi=0,9) (note 1) | 0.97 | |
| Mechanical and Environment | | |
| Height | 88 | mm |
| Width | 240 | mm |
| Length (without connections and cable clamps) | 360 | mm |
| Weight (including cooling water) | 9.5 | kg |
| Coolant pressure drop @ 6l/min, Tcoolant = 25°C (note 2) | 65 | hPa |
| Power dissipation to coolant (IAC = IACcont) | 2.4 | kW |
| Operational ambient temperature range | -40...+85 | °C |
| protection grade | IP65 | |
| Connections | | |
| DC Input: 2 cable shoes M8; max cable cross section | 50 | mm2 |
| AC output: 3 cable shoes M8; max cable cross section | 50 | mm2 |
| 23 pole AMP control connector, wire cross section | 0.5 | mm2 |
| Universal 14 pole Motor Sensor Interface connector | | |
| Recommended coolant hose inside diameter | 14 | mm |
| Note 1: 100% AC Sine Modulation, Phase-to-Phase AC Voltage amplitude = VDC | | |
| Note 2: coolant = water / glycol, 50/50 | | |